Healthy homes standards compliance statement
Tenancy
- Address of tenancy
- 12 Example Street, Palmerston North
- Landlord or landlords
- A. Landlord
- Tenancy agreement start date
- 1 October 2026
- Healthy homes compliance date for this tenancy
- 1 July 2025
- Compliance with the healthy homes standards
- I/we, A. Landlord, comply with the healthy homes standards as required by section 45(1)(bb) or 66I(1)(bb) of the Residential Tenancies Act 1986.
Heating
Regulation 34
- Heating exemption
- No heating exemption applies.
- Required heating capacity of the main living room
- 5.2 kW
- How the required capacity was worked out
- The heating assessment tool at tenancy.govt.nz
- Heater 1: type and heating capacity
- Heat pump, 6 kW. Lounge, north wall
- Tolerance or top-up allowance for existing heaters
- Does not apply.
Insulation
Regulation 35 and section 13A of the Residential Tenancies Act 1986
- Ceiling insulation
- Installed above all domestic living spaces
- Ceiling insulation R-value when installed
- R3.2
- Ceiling insulation type
- Glass wool segments
- Ceiling insulation condition
- Reasonable condition, without mould, dampness, damage or gaps
- Ceiling insulation installed
- 20 May 2019
- Ceiling insulation last inspected
- 12 September 2026
- Underfloor insulation
- Installed under all suspended floors of domestic living spaces
- Underfloor insulation R-value when installed
- R1.4
- Underfloor insulation type
- Polyester blanket
- Underfloor insulation condition
- Reasonable condition, without mould, dampness, damage or gaps
- Underfloor insulation installed
- 20 May 2019
- Underfloor insulation last inspected
- 12 September 2026
- Wall insulation
- Installed in some areas: Rear extension only (bedroom 3 and the laundry)
- Wall insulation type
- Glass wool segments, as shown in the 2012 building consent for the extension
- Wall insulation condition
- Unknown: the walls are lined and were not opened
- Insulation information that could not be obtained
- The condition of the wall insulation in the rear extension. Why: The walls are lined, and checking would mean removing wall linings. The council property file records the type but not the condition. The landlord confirms that all reasonable efforts have been made to obtain this information.
Ventilation
Regulation 36
- Openable windows and doors
- Every habitable space has one or more windows, doors or skylights that open to the outside, can be fixed open, and together make up at least 5% of the room's floor area.
- Kitchen
- Extractor fan venting to the outside, 150 mm diameter. Ducted rangehood.
- Bathroom
- Extractor fan venting to the outside, 120 mm diameter.
Moisture ingress and drainage
Regulation 38
- Drainage
- The tenancy building has an efficient drainage system for removing storm water, surface water and ground water to an appropriate outfall. Gutters and downpipes discharge to the council stormwater system.
- Enclosed subfloor
- The building has an enclosed subfloor space.
- Ground moisture barrier
- Each enclosed subfloor has a ground moisture barrier. Polythene sheet, installed 20 May 2019.
Draught stopping
Regulation 37
- Open fireplace 1: Lounge
- Closed off, with the chimney blocked.
- Gaps and holes
- The premises are free from unintentional and unreasonable gaps and holes that allow noticeable draughts into or out of the building.
- Draught stopping work done
- Door seals on front and back doors, window latches repaired, lounge chimney capped and fireplace opening sealed
Landlord statement
- Declaration
- I/we, A. Landlord, declare that the information contained in this statement is true and correct as at the date of signing.
- Signed by (landlord or landlords)
- Left blank, to be completed by hand
- Date signed
- Left blank, to be completed by hand